BP1716/20
1,716 nm narrowband filter, 20 nm wide, with OD4 blocking from 200 to 1,695 nm and from 1,732 to 2,000 nm.
Need a different size or spec? We make custom versions.
BANDOPTIC spectrum engine
Interactive Spectrum
Plot and compare optical filter spectra. Catalog curves digitized from the supplied PDFs are approximate references; request measured data for specifications.
Catalog curves are approximate digital tracings of PDF graph images, not instrument CSV or guaranteed production-lot results. Some curves show only the plotted peak or cut-on edge; open the source graph for its full context. For approximate traces, OD values at or below 2% transmission are hidden because raster plots cannot verify blocking performance. Uploaded CSV files stay in your browser. Andover numerical curves will be added only when source data is available.
Technical Specifications
| Specification | Value |
|---|---|
| Center wavelength (CWL) | 1,716 ± 2 nm |
| Bandwidth (FWHM) | 20 ± 2 nm |
| Transmission | > 95% at 1,716 nm |
| Blocking, short side | OD > 4 (average), 200–1,695 nm |
| Blocking, long side | OD > 4 (average), 1,732–2,000 nm |
| Angle of incidence | 0 ± 2° |
| Cone half-angle | 3.5° |
| Substrate | Optical glass (K9 / B270) |
| Thickness | 1.0 ± 0.1 mm |
| Dimensional tolerance | +0 / −0.1 mm |
| Surface quality | 60-40 scratch-dig |
| Clear aperture | ≥ 90% of diameter |
Sizes
Need custom requirements? We cut to your drawing.
| Size | Thickness | Mount |
|---|---|---|
| Ø12.5 mm | 1.0 mm | Unmounted |
| Ø25 mm | 1.0 mm | Unmounted or ringed |
| 12.5 × 12.5 mm | 1.0 mm | Unmounted |
Other sizes and shapes are cut to order.
Choosing This Filter
BP1716/20 passes a 20 nm band at 1,716 nm, beyond the reach of standard InGaAs, for extended-range InGaAs detectors and SWIR spectrometers. The region around 1,700 nm is where many hydrocarbons and plastics absorb strongly, so a single band here can pick out one material feature. Transmission is above 95% at the line, and OD4 blocking from 200 to 1,695 nm and from 1,732 to 2,000 nm keeps the rest of the SWIR out. The model name carries no OD suffix, but its blocking is specified at OD4. For a band at 1,650 nm, see BP1650/20,OD4.
Customization Options
Need a different wavelength, width or blocking? We design it to order.
We can move the center wavelength anywhere from 200 to 2,500 nm, change the width, block deeper, up to OD6, or further into the infrared, and cut the filter to your size and thickness.
Tell us your light source, your detector and the numbers you need. We will reply with a recommended design and a quote, from a single prototype to production volumes.
See what we can make on our custom filters page. Learn more
Related Filters
FAQs
Can I tilt this filter?
A small tilt, up to about 2°, stays within spec. Beyond that, the passband moves to shorter wavelengths, and the further you tilt, the further it moves. If your design needs a tilt, tell us the angle and we will design for it.
How should I clean and store it?
Hold the filter by its edges. Blow off dust first, then wipe gently with lens tissue and reagent-grade isopropyl alcohol if needed. Store it dry, in its case, away from direct sunlight.
Can I get the measured curve with my order?
Yes. Ask for it when you order, and we include the measured transmission of your batch, as a chart and as a data file.
Don’t see the filter you need? Tell us about your system and we will suggest one or design it. Learn more