Infrared Filters
Pick a standard filter below, or send us your wavelength for a custom design.
Infrared Bandpass Filters from 1.8 to 7.35 µm
Infrared detectors respond to a wide spread of wavelengths, but a gas line, a laser or a temperature reading lives in one narrow band. Our infrared filters pass that band in the short-wave or mid-infrared and block everything from the visible up to 3 µm, or up to 11–12 µm.
In the short-wave infrared we make filters at 1,810, 1,940 and 2,100 nm, 30 to 50 nm wide, with more than 92% transmission and OD4 to OD6 blocking.
In the mid-infrared we make filters at 3.95, 4.75 and 7.35 µm, 100 to 200 nm wide, with 65 to 80% transmission and OD2 blocking.
We also make filters for infrared thermometers and windows for thermal-imaging sensors; see the section below.
Infrared bandpass filters from 2 to 14 µm can be 1% to 50% of the center wavelength wide, with more than 80% typical transmission and OD3 average blocking, on germanium, silicon, zinc selenide or sapphire. Diamond-like carbon (DLC) coatings protect germanium and silicon optics against humidity, salt fog and abrasion.
Need another infrared band? Ask us for a custom design. Specify a custom filter
Which Infrared Band Do You Need?
Infrared is usually split into short-wave (about 1 to 3 µm), mid-wave (about 3 to 5 µm) and long-wave (about 8 to 14 µm). Detectors, sources and window materials change from one band to the next.
Our 1.8 to 2.1 µm filters suit short-wave infrared detectors and lasers. Our 3.95 and 4.75 µm filters sit in the mid-wave band; 7.35 µm lies between the mid-wave and long-wave bands.
Typical uses for mid-infrared bandpass filters include non-contact temperature measurement and gas sensing. Tell us your detector and source, and we will check which band fits.
Three Groups of Infrared Filter
D01 · IMAGE PENDINGSWIR bandpass curveSWIR Bandpass, 1.8–2.1 µm
Filters at 1,810, 1,940 and 2,100 nm for short-wave infrared detectors and lasers: center held to ±2 nm, 30 or 50 nm wide, more than 92% transmission, and OD4 or OD6 blocking from 400 to 3,000 nm.
D02 · IMAGE PENDINGMid-infrared bandpass curveMid-IR Bandpass, 3.95–7.35 µm
Filters at 3.95, 4.75 and 7.35 µm for temperature and gas sensing: center held to ±30 nm, 100 to 200 nm wide, more than 80% transmission (65% at 7.35 µm), and OD2 blocking from 400 nm to 11 or 12 µm.
Thermometry & Thermal Imaging
Filters for infrared thermometer sensors and windows for thermal-imaging cameras, made to your detector’s package and band. Specifications on request.
How We Specify and Measure Infrared Filters
Our Cary 5000 spectrophotometer measures to 3,300 nm, which covers our short-wave infrared filters, blocking bands included.
Mid-infrared filters at 3.95 µm and beyond need Fourier-transform infrared (FTIR) measurement. The curves we supply for them come from our FTIR measurement.
Tolerances scale with wavelength. ±2 nm at 1,810 nm is about 0.1% of the center; ±30 nm at 3,950 nm is about 0.8%. Both are tight relative to their 30 to 200 nm bandwidths.
Filters for Infrared Thermometers and Thermal Imaging
Non-contact thermometers and thermal sensors read the infrared light an object emits. A filter on the sensor window sets which band the sensor sees, and the rest of the spectrum is blocked.
- Detector type and package (for example, TO can)
- Wavelength band to pass
- Blocking range below and above the band
- Window or filter diameter and thickness
- Operating temperature range
- Quantity
We supply thermometer filters for sensor packages and windows for thermal-imaging detectors, alongside our mid-infrared bandpass filters. Send us your detector type, package size and the band you need.
Standard Infrared Filters
| Model | CWL (nm) | FWHM (nm) | Avg. T | Blocking | Blocking range (nm) | AOI |
|---|---|---|---|---|---|---|
| BPF1810-30 | 1,810 ± 2 | 30 ± 2 | > 92% | OD4 | 400–1,785 / 1,842–3,000 | 0° |
| BPF1940-50 | 1,940 ± 2 | 50 ± 2 | > 92% | OD6 | 400–1,900 / 2,000–3,000 | 0° |
| BPF2100-50 | 2,100 ± 2 | 50 ± 2 | > 92% | OD6 | 400–2,062 / 2,145–3,000 | 0° |
| BPF3950-100 | 3,950 ± 30 | 100 ± 20 | > 80% | OD2 | 400–11,000 | 0° |
| BPF4750-180 | 4,750 ± 30 | 180 ± 20 | > 80% | OD2 | 400–11,000 | 0° |
| BPF7350-200 | 7,350 ± 30 | 200 ± 20 | > 65% | OD2 | 400–12,000 | 0° |
All specified at 0° with a 3.5° cone half-angle. Mid-infrared blocking covers the stated range outside the passband.
Need a different infrared band? Send us the center wavelength and width, the blocking range, your detector and package, the operating temperature and the size, and we will reply with a quote and a recommended design. Contact us