Narrowband Filters

Pick a standard filter below, or send us your wavelength for a custom design.

Narrow Bandpass Filters for Laser Lines and SWIR Sensing

When your signal is a single laser line or a narrow emission band, a wide filter lets in too much light around it. A narrowband filter passes only a few nanometers around the line and blocks the rest, so the detector sees your signal, not the background.

We make narrowband filters from 532 to 1,716 nm, 4 to 25 nm wide, with more than 90% of the in-band light getting through.

Outside the passband they block to OD3–OD6, so sunlight, room light and other laser lines stay off the sensor. Each filter’s blocking range is in the table below.

Center wavelength is held to ±2 nm on most designs, so the passband stays on your line. Filters for 1,064 and 1,550 nm LiDAR receivers are made to sit at a 3° tilt; the others work face-on.

Hard-coated narrowband filters from 334 to 1,550 nm, 10 to 25 nm wide, block to OD4 on average from 200 to 1,200 nm and suit high-temperature use.

Narrowband Laser Line FiltersP01 · IMAGE PENDINGNarrowband laser-line filters

Working at another line? We design narrowband filters to order from 200 to 2,500 nm, 3 to 20 nm wide. Specify a custom filter

Narrowband, Bandpass or Ultra-Narrow?

There is no industry rule for where “narrow” starts. On this site, bandpass filters are 20 nm and wider, narrowband filters are about 4 to 25 nm, and ultra-narrow filters are below 2 nm. Learn more

A narrower passband rejects more background around the line, but it leaves less room for error. A 10 nm filter whose center has drifted 4 nm loses a large part of the signal; a 40 nm filter barely notices.

So the narrower you go, the more the angle of incidence, the cone angle and the operating temperature matter. The next two sections put numbers on both. For lines below 2 nm, see ultra-narrow filters. Learn more

How Far Does the Passband Move When You Tilt the Filter?

Tilting an interference filter moves its passband to shorter wavelengths. In collimated light up to about 15°, the shift follows λθ = λ0 × √(1 − (sin θ / N*)2), where N* is the filter’s effective index.

Worked example for a 1,064 nm filter. With N* = 2.05: about 1.0 nm at 5°, 3.8 nm at 10° and 8.5 nm at 15°. With N* = 1.45: about 1.9 nm, 7.7 nm and 17.1 nm.

On a 10 nm FWHM filter, a 10° tilt can move the center by 40 to 75% of the bandwidth. On a 4 nm filter, even 5° matters. That is why each spec states its angle of incidence.

Reference illustration of an 800 nm filter shifting with angle of incidenceD01 · IMAGE PENDINGA 1,064 nm narrowband filter shifting with angle from 0 to 15 degrees

Increasing the angle of incidence shifts an 800 nm filter passband toward shorter wavelengths.

In a converging or diverging beam, the shift is smaller: roughly half the collimated value at the same angle, for full cone angles up to 20°. Unless a filter says otherwise, we specify it for a cone half-angle of 3.5°, about f/8. If your optics are faster, tell us.

Our LiDAR filters are designed for 3 ± 2° incidence: mount them at that tilt and they sit on the laser line. Ask us for the effective index (N*) of any filter; we supply it with the design data. Full method

Collimated ConvergingD02 · IMAGE PENDINGCollimated versus converging light on a filter

Tilting an interference filter moves its passband to shorter wavelengths. In collimated light up to about 15°, the shift follows λθ = λ0 × √(1 − (sin θ / N)²), where N is the filter’s effective index.

Temperature moves the passband too: it shifts to longer wavelengths as the filter warms and shorter as it cools. Industry figures are about 0.01 to 0.035 nm per °C between 200 and 1,200 nm. Over a 60 °C operating range, that is 0.6 to 2.1 nm, small on a 40 nm filter but up to half the bandwidth of a 4 nm one. We can measure the coefficient of your part at your wavelength. If your system runs outdoors or warms up in use, tell us the temperature range and we will size the bandwidth so the line stays inside it.

What to Specify for a Narrowband Filter

Have these ready when you ask for a quote. If you don’t know some of them, tell us your laser and detector and we will help fill in the rest:

  • Center wavelength and tolerance (±2 nm standard)
  • FWHM and its tolerance
  • Average or minimum in-band transmission
  • Blocking OD and the full range to block
  • Angle of incidence and cone half-angle
  • Operating temperature range
  • Size, thickness and mounting

Related Filter Types

Standard Narrowband Filters

Model CWL (nm) FWHM (nm) Avg. T Blocking Blocking range (nm) AOI Use
BP532-10,OD6 532 10 > 92% OD6 350–1100 0° General
BP650/10,OD6 650 10 > 92% OD6 350–1100 0° General
BP780/10,OD6 780 10 > 90% OD6 350–1100 0° General
BP940/10,OD6 940 10 > 95% OD6 200–1100 0° General
BP1064-4nm,OD5 1064 4 > 90% OD5 350–1100 3° LiDAR
BP1064-6,OD4 1064 6 > 90% OD5 / OD4 200–1800 3° LiDAR
BP1064/10,OD6 1064 10 > 95% OD6 350–1100 0° General
BPF1064-10nm,OD5 1064 10 > 92% OD5 350–1200 3° LiDAR
BPF1150-10,OD4 1150 10 > 90% OD4 300–1800 0° General
BP1175/10,OD3 1175 10 > 95% OD3 300–1800 0° General
BPF1185-15,OD3 1185 15 > 93% OD3 300–1800 0° General
BP1200/10,OD3 1200 10 > 95% OD3 300–1800 0° General
BPF1200-15,OD3 1200 15 > 93% OD3 200–1800 0° General
BPF1215-15,OD3 1215 15 > 93% OD3 300–1800 0° General
BPF1285-25,OD3 1285 25 > 93% OD3 800–2000 0° General
BP1350/15,OD3 1350 15 > 98% OD3 300–1800 0° General
BPF1370-15,OD3 1370 15 > 93% OD3 300–1800 0° General
BP1425/25,OD3 1425 25 > 98% OD3 800–2000 0° General
BPF1550-20,OD3 1550 20 > 93% OD3 300–1800 0° General
BP1550-20,OD5 1550 20 > 92% OD5 900–1800 3° LiDAR
BP1650/20,OD4 1650 20 > 95% OD4 200–1800 0° General
BPF1660-15,OD3 1660 15 > 95% OD3 300–1800 0° General
BP1716/20 1716 20 > 95% OD4 200–2000 0° General

We have about 90 more standard designs from 370 to 1,695 nm, 10 to 20 nm wide. Get the full list

Don’t see your line? Send us the center wavelength, FWHM, blocking OD and range, angle of incidence, cone angle and operating temperature, and we will reply with a quote and a recommended design. Contact us