Bandpass Filters
Pick a standard filter below, or send us your wavelength for a custom design.
Optical Bandpass Filters from 375 to 1,064 nm, Blocked to OD6
If your detector should see one band of light and nothing else, a bandpass filter does that job: it passes one band of wavelengths and blocks the light on both sides.
We make standard bandpass filters from 375 to 1,064 nm, 20 to 80 nm wide, passing more than 90% of the light in the band.
Outside the band they block to OD2–OD6, usually out to 1,100 nm, where silicon detectors stop responding, so stray light across your sensor’s range stays out.
Center wavelength and bandwidth are held to ±2 nm on most designs. Most filters are made to sit face-on to the beam; our LiDAR filters are made for a 3° tilt.
Our standard bandpass filters carry an expected field life of 10 to 20 years, thanks to proprietary stabilization and sealing. For harsh or hot environments, hard-coated narrowband versions use plasma-deposited hard-oxide layers on borosilicate glass, with no absorbing filter glass.
Need another wavelength? We coat custom bandpass filters from 200 to 2,500 nm, with bandwidths from 20 to 200 nm. Specify a custom filter
What the Numbers on a Bandpass Spec Mean
Take a 532 nm filter, 40 nm wide, blocked to OD6. The center wavelength (CWL), 532 ± 2 nm, is the middle of the passband. The bandwidth, 40 ± 2 nm, is its full width at half the peak transmission (FWHM). Average transmission across the band is above 95%.
Blocking is given as optical density over a stated range: an average above OD6 from 350 to 506 nm and from 560 to 1,100 nm. OD6 lets one part in a million through; OD3 lets one part in a thousand through.
The angle of incidence, 0 ± 2°, and the cone half-angle, 3.5°, describe how the filter was designed to be used. Tilt it further or put it in a faster cone, and the passband moves to shorter wavelengths. Full guide
Edge Steepness and Blocking Depth
A bandpass filter is a stack of thin-film Fabry–Perot cavities. One cavity gives a rounded peak; each cavity added squares off the shoulders and steepens the edges.
Typical design figures: at 10% transmission, a one-cavity filter is about 2.5–3 times its FWHM wide, a six-cavity filter about 1.1 times. At 0.1%, one cavity spreads to 15–20 times its FWHM; six cavities stay under 2 times.
Steeper edges let you place a bandpass close to a laser line or a neighbouring fluorescence channel without cutting into your signal. They need more layers and tighter process control.
D01 · IMAGE PENDINGTransmission of one-, two- and four-cavity bandpass filtersBlocking depth is a separate choice. Fluorescence filters need deep blocking, OD6 on average, because the emission signal is far weaker than scattered excitation light. LiDAR and NIR receivers usually do well with OD3 to OD5.
A spectrophotometer cannot read very deep blocking. Above about OD6, the measured curve flattens at the instrument’s limit; the blocking we guarantee is the value stated for each filter.
T01 · IMAGE PENDINGMeasured spectrum of BP532-40,OD6The passband illustrates the difference between full width at half maximum (FWHM) and guaranteed minimum bandwidth (GMBW).
Choosing a Bandpass Filter
Start from your light source, your detector and your optics. These five points decide most choices:
- Bandwidth. For fluorescence emission, cover the dye’s emission peak and stay clear of the excitation filter’s edge; the emission filters in our sets are 20 to 60 nm wide. For a single laser line, a narrowband filter is usually the better fit. Learn more
- Very narrow lines. Below about 2 nm FWHM, for Raman lasers or atomic lines, use an ultra-narrow filter. Learn more
- Angle and temperature. The passband moves to shorter wavelengths as the angle of incidence grows, and drifts by a few hundredths of a nanometre per °C. Tell us your angle, cone and operating temperature. Learn more
- Blocking range. Make sure blocking covers your detector’s whole response. Silicon detectors need blocking to about 1,100 nm; for InGaAs, choose a filter blocked to 1,200 nm or beyond.
- Matched sets. For fluorescence instruments, buy excitation, emission and dichroic together, so the edges are designed not to overlap. Learn more
Related Filter Types
- Multiband filters for several sources at once Learn more
- LiDAR filters for 905, 940, 1,064 and 1,550 nm Learn more
- Fluorescence microscopy filters Learn more
Standard Bandpass Filters
| Model | CWL (nm) | FWHM (nm) | Avg. T | Blocking | Blocking range (nm) | AOI | Use |
|---|---|---|---|---|---|---|---|
| BP375/28 | 375 | 28 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP405-30,OD3 | 405 | 30 | > 90% | OD3 | 350–1100 | 0° | General |
| BPF420-30,OD6 | 420 | 30 | > 92% | OD6 | 200–1100 | 0° | Fluorescence |
| BP430/24 | 430 | 24 | ≥ 90% | OD6 avg | 350–800 | — | qPCR / microscopy set |
| BPF450-30,OD6 | 450 | 30 | > 92% | OD6 | 350–1100 | 0° | Fluorescence |
| BP450-60,OD3 | 450 | 60 | > 95% | OD3 | 350–1100 | 0° | General |
| BP460/55 | 460 | 55 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP480/30 | 480 | 30 | ≥ 90% | OD6 avg | 350–800 | — | qPCR / microscopy set |
| BPF480-40/1500,OD4 | 480 | 40 | > 93% | OD4 / OD3 | 300–1500 | 0° | Fluorescence |
| BP530/20 | 530 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BP530/40 | 530 | 40 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP532-40,OD6 | 532 | 40 | > 95% | OD6 | 350–1100 | 0° | General |
| BP535/40 | 535 | 40 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP543/20 | 543 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BPF550-48,OD4 | 550 | 48 | > 95% | OD4 | 350–1100 | 0° | Fluorescence |
| BP560/40 | 560 | 40 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP565/22 | 565 | 22 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BP585/20 | 585 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BPF590-50,OD6 | 590 | 50 | > 92% | OD6 | 350–900 | 0° | Fluorescence |
| BPF600-48,OD6 | 600 | 48 | > 92% | OD6 | 350–1100 | 0° | Fluorescence |
| BP605/55 | 605 | 55 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP612/20 | 612 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BP620/20 | 620 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BP624/40 | 624 | 40 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP630/20 | 630 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BPF630-30,OD6 | 630 | 30 | > 90% | OD6 | 200–1050 | 0° | Fluorescence |
| BP635/60 | 635 | 60 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BP655/20 | 655 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BPF660-20,OD6 | 660 | 20 | > 92% | OD6 | 350–1100 | 0° | Fluorescence |
| BPF660-40,OD6 | 660 | 40 | > 93% | OD6 | 350–1100 | 0° | Fluorescence |
| BPF660-75,OD6 | 660 | 75 | > 92% | OD6 | 200–1100 | 0° | Fluorescence |
| BPF670-20,OD6 | 670 | 20 | > 90% | OD6 | 200–1100 | 0° | Fluorescence |
| BP675/20 | 675 | 20 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BPF690-80,OD6 | 690 | 80 | > 92% | OD6 | 350–1100 | 0° | Fluorescence |
| BP694/40 | 694 | 40 | ≥ 90% | OD6 avg | — | — | Microscopy set |
| BPF695-40,OD6 | 695 | 40 | > 93% | OD6 | 200–1100 | 0° | Fluorescence |
| BPF720-20,OD6 | 720 | 20 | > 93% | OD6 | 350–1100 | 0° | General |
| BP725/30 | 725 | 30 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BP800/30 | 800 | 30 | ≥ 90% | OD6 avg | 350–800 | — | qPCR set |
| BP808-60,OD3 | 808 | 60 | > 95% | OD3 | 350–1100 | 0° | General |
| BPF850-30,OD3 | 850 | 30 | > 92% | OD3 | 200–1100 | 0° | General |
| BP940-26,OD5 | 940 | 26 | > 95% | OD5 | 350–1100 | 3° | LiDAR |
| BPF940-55,OD3 | 940 | 55 | > 92% | OD3 | 350–1100 | 0° | General |
| BPP940-60,OD3 | 940 | 60 | > 92% | OD3 | 350–1100 | 3° | LiDAR |
| BPF980-55,OD5 | 980 | 55 | > 90% | OD5 | 200–1100 | 0° | General |
| BP980-60,OD2 | 980 | 60 | > 98% | OD2 | 300–1150 | 3° | LiDAR |
| BPF1064-30nm,OD5 | 1064 | 30 | > 92% | OD5 | 350–1200 | 3° | LiDAR |
| BP1064-40,OD6 | 1064 | 40 | > 92% | OD6 | 200–1100 | 0° | LiDAR |
| BPF1064-40,OD5 | 1064 | 40 | > 95% | OD5 | 350–1200 | 0° | General |
| BPF1064-40nm,OD5 | 1064 | 40 | > 93% | OD5 | 350–1200 | 3° | LiDAR |
Filters used in our qPCR and microscopy sets pass at least 90% on average and block to OD6.
Filters used in our qPCR and microscopy sets pass at least 90% on average and block to OD6. We have more than 170 further standard designs, 20 to 60 nm wide. Get the full list
Don’t see your wavelength? Send us your center wavelength, bandwidth, blocking OD and range, size, angle of incidence and operating temperature, and we will reply with a quote and a recommended spec. Contact us