Bandpass Filters

Pick a standard filter below, or send us your wavelength for a custom design.

Optical Bandpass Filters from 375 to 1,064 nm, Blocked to OD6

If your detector should see one band of light and nothing else, a bandpass filter does that job: it passes one band of wavelengths and blocks the light on both sides.

We make standard bandpass filters from 375 to 1,064 nm, 20 to 80 nm wide, passing more than 90% of the light in the band.

Outside the band they block to OD2–OD6, usually out to 1,100 nm, where silicon detectors stop responding, so stray light across your sensor’s range stays out.

Center wavelength and bandwidth are held to ±2 nm on most designs. Most filters are made to sit face-on to the beam; our LiDAR filters are made for a 3° tilt.

Our standard bandpass filters carry an expected field life of 10 to 20 years, thanks to proprietary stabilization and sealing. For harsh or hot environments, hard-coated narrowband versions use plasma-deposited hard-oxide layers on borosilicate glass, with no absorbing filter glass.

Mounted and unmounted optical bandpass filters

Need another wavelength? We coat custom bandpass filters from 200 to 2,500 nm, with bandwidths from 20 to 200 nm. Specify a custom filter

What the Numbers on a Bandpass Spec Mean

Take a 532 nm filter, 40 nm wide, blocked to OD6. The center wavelength (CWL), 532 ± 2 nm, is the middle of the passband. The bandwidth, 40 ± 2 nm, is its full width at half the peak transmission (FWHM). Average transmission across the band is above 95%.

Blocking is given as optical density over a stated range: an average above OD6 from 350 to 506 nm and from 560 to 1,100 nm. OD6 lets one part in a million through; OD3 lets one part in a thousand through.

The angle of incidence, 0 ± 2°, and the cone half-angle, 3.5°, describe how the filter was designed to be used. Tilt it further or put it in a faster cone, and the passband moves to shorter wavelengths. Full guide

Edge Steepness and Blocking Depth

A bandpass filter is a stack of thin-film Fabry–Perot cavities. One cavity gives a rounded peak; each cavity added squares off the shoulders and steepens the edges.

Typical design figures: at 10% transmission, a one-cavity filter is about 2.5–3 times its FWHM wide, a six-cavity filter about 1.1 times. At 0.1%, one cavity spreads to 15–20 times its FWHM; six cavities stay under 2 times.

Steeper edges let you place a bandpass close to a laser line or a neighbouring fluorescence channel without cutting into your signal. They need more layers and tighter process control.

Cavity ComparisonD01 · IMAGE PENDINGTransmission of one-, two- and four-cavity bandpass filters

Blocking depth is a separate choice. Fluorescence filters need deep blocking, OD6 on average, because the emission signal is far weaker than scattered excitation light. LiDAR and NIR receivers usually do well with OD3 to OD5.

A spectrophotometer cannot read very deep blocking. Above about OD6, the measured curve flattens at the instrument’s limit; the blocking we guarantee is the value stated for each filter.

Bandpass definition reference illustrating FWHM and guaranteed minimum bandwidthT01 · IMAGE PENDINGMeasured spectrum of BP532-40,OD6

The passband illustrates the difference between full width at half maximum (FWHM) and guaranteed minimum bandwidth (GMBW).

Choosing a Bandpass Filter

Start from your light source, your detector and your optics. These five points decide most choices:

  • Bandwidth. For fluorescence emission, cover the dye’s emission peak and stay clear of the excitation filter’s edge; the emission filters in our sets are 20 to 60 nm wide. For a single laser line, a narrowband filter is usually the better fit. Learn more
  • Very narrow lines. Below about 2 nm FWHM, for Raman lasers or atomic lines, use an ultra-narrow filter. Learn more
  • Angle and temperature. The passband moves to shorter wavelengths as the angle of incidence grows, and drifts by a few hundredths of a nanometre per °C. Tell us your angle, cone and operating temperature. Learn more
  • Blocking range. Make sure blocking covers your detector’s whole response. Silicon detectors need blocking to about 1,100 nm; for InGaAs, choose a filter blocked to 1,200 nm or beyond.
  • Matched sets. For fluorescence instruments, buy excitation, emission and dichroic together, so the edges are designed not to overlap. Learn more

Related Filter Types

  • Multiband filters for several sources at once Learn more
  • LiDAR filters for 905, 940, 1,064 and 1,550 nm Learn more
  • Fluorescence microscopy filters Learn more

Standard Bandpass Filters

Model CWL (nm) FWHM (nm) Avg. T Blocking Blocking range (nm) AOI Use
BP375/28 375 28 ≥ 90% OD6 avg — — Microscopy set
BP405-30,OD3 405 30 > 90% OD3 350–1100 0° General
BPF420-30,OD6 420 30 > 92% OD6 200–1100 0° Fluorescence
BP430/24 430 24 ≥ 90% OD6 avg 350–800 — qPCR / microscopy set
BPF450-30,OD6 450 30 > 92% OD6 350–1100 0° Fluorescence
BP450-60,OD3 450 60 > 95% OD3 350–1100 0° General
BP460/55 460 55 ≥ 90% OD6 avg — — Microscopy set
BP480/30 480 30 ≥ 90% OD6 avg 350–800 — qPCR / microscopy set
BPF480-40/1500,OD4 480 40 > 93% OD4 / OD3 300–1500 0° Fluorescence
BP530/20 530 20 ≥ 90% OD6 avg 350–800 — qPCR set
BP530/40 530 40 ≥ 90% OD6 avg — — Microscopy set
BP532-40,OD6 532 40 > 95% OD6 350–1100 0° General
BP535/40 535 40 ≥ 90% OD6 avg — — Microscopy set
BP543/20 543 20 ≥ 90% OD6 avg 350–800 — qPCR set
BPF550-48,OD4 550 48 > 95% OD4 350–1100 0° Fluorescence
BP560/40 560 40 ≥ 90% OD6 avg — — Microscopy set
BP565/22 565 22 ≥ 90% OD6 avg 350–800 — qPCR set
BP585/20 585 20 ≥ 90% OD6 avg 350–800 — qPCR set
BPF590-50,OD6 590 50 > 92% OD6 350–900 0° Fluorescence
BPF600-48,OD6 600 48 > 92% OD6 350–1100 0° Fluorescence
BP605/55 605 55 ≥ 90% OD6 avg — — Microscopy set
BP612/20 612 20 ≥ 90% OD6 avg 350–800 — qPCR set
BP620/20 620 20 ≥ 90% OD6 avg 350–800 — qPCR set
BP624/40 624 40 ≥ 90% OD6 avg — — Microscopy set
BP630/20 630 20 ≥ 90% OD6 avg 350–800 — qPCR set
BPF630-30,OD6 630 30 > 90% OD6 200–1050 0° Fluorescence
BP635/60 635 60 ≥ 90% OD6 avg — — Microscopy set
BP655/20 655 20 ≥ 90% OD6 avg 350–800 — qPCR set
BPF660-20,OD6 660 20 > 92% OD6 350–1100 0° Fluorescence
BPF660-40,OD6 660 40 > 93% OD6 350–1100 0° Fluorescence
BPF660-75,OD6 660 75 > 92% OD6 200–1100 0° Fluorescence
BPF670-20,OD6 670 20 > 90% OD6 200–1100 0° Fluorescence
BP675/20 675 20 ≥ 90% OD6 avg 350–800 — qPCR set
BPF690-80,OD6 690 80 > 92% OD6 350–1100 0° Fluorescence
BP694/40 694 40 ≥ 90% OD6 avg — — Microscopy set
BPF695-40,OD6 695 40 > 93% OD6 200–1100 0° Fluorescence
BPF720-20,OD6 720 20 > 93% OD6 350–1100 0° General
BP725/30 725 30 ≥ 90% OD6 avg 350–800 — qPCR set
BP800/30 800 30 ≥ 90% OD6 avg 350–800 — qPCR set
BP808-60,OD3 808 60 > 95% OD3 350–1100 0° General
BPF850-30,OD3 850 30 > 92% OD3 200–1100 0° General
BP940-26,OD5 940 26 > 95% OD5 350–1100 3° LiDAR
BPF940-55,OD3 940 55 > 92% OD3 350–1100 0° General
BPP940-60,OD3 940 60 > 92% OD3 350–1100 3° LiDAR
BPF980-55,OD5 980 55 > 90% OD5 200–1100 0° General
BP980-60,OD2 980 60 > 98% OD2 300–1150 3° LiDAR
BPF1064-30nm,OD5 1064 30 > 92% OD5 350–1200 3° LiDAR
BP1064-40,OD6 1064 40 > 92% OD6 200–1100 0° LiDAR
BPF1064-40,OD5 1064 40 > 95% OD5 350–1200 0° General
BPF1064-40nm,OD5 1064 40 > 93% OD5 350–1200 3° LiDAR

Filters used in our qPCR and microscopy sets pass at least 90% on average and block to OD6.

Filters used in our qPCR and microscopy sets pass at least 90% on average and block to OD6. We have more than 170 further standard designs, 20 to 60 nm wide. Get the full list

Don’t see your wavelength? Send us your center wavelength, bandwidth, blocking OD and range, size, angle of incidence and operating temperature, and we will reply with a quote and a recommended spec. Contact us