Multiband Filters

Pick a standard filter below, or send us your wavelength for a custom design.

Dual and Triple Bandpass Filters, One Filter for Several Channels

A multiband filter has two or three passbands in one coating, so a single filter can serve several light sources or detection channels at once.

We make standard designs with bands from 310 to 1,665 nm, each passing more than 90% of its light.

Band widths range from 10 nm for line sources up to 250 nm for a full visible band paired with an 850 or 940 nm infrared band.

Custom multiband filters can place bands anywhere from 200 to 2,500 nm, 3 to 250 nm wide, with OD2 to OD4 blocking between them.

Dual-band designs are also made for key laser lines such as 1,064 and 1,550 nm, and two bands can be combined anywhere from the UV to the infrared.

Multiband Optical Filter ProductP01 · IMAGE PENDINGMultiband filters

Our standard designs are made to sit face-on to the beam. Specify a custom filter

Why Use a Multiband Filter?

Instead of switching between filters, you leave one in place. Each band is centered on one of your sources, and the regions between the bands are blocked, so each channel stays clean without moving parts.

The trade-off is design freedom. Each extra band adds layers and narrows the room between bands, so blocking between bands is usually OD2 to OD4 rather than the OD6 possible with a single band.

If your sources fire one at a time, a multiband filter keeps the optical path fixed while the light changes. If they fire together, check that each detector channel has its own color filter or a separate emission filter.

Three Common Multiband Layouts

Visible plus infrared. Day-and-night cameras need to see color by day and an infrared illuminator by night. A dual-band filter does both: a broad visible band, about 250 nm wide, plus a 50 nm band at 850 or 940 nm.

Two or three narrow lines. When you work with specific LED or laser lines, such as 500 and 655 nm, 310 and 400 nm, or 650 and 850 nm, narrow bands pass each line and block the light between them.

Visible 850nm Dual BandD01 · IMAGE PENDINGVisible plus 850 nm dual-band filter curve
Figure: Visible plus 850 nm dual-band filter curve.

Red, green and blue. Triple-band designs, for example 450, 550 and 650 nm with 30 nm bands, pass three visible channels at once.

Figure: Measured spectrum of Multi-450/555/685.

Near-infrared and SWIR pairs. For longer wavelengths we make pairs and triples such as 660 and 860 nm, 550, 720 and 850 nm, and narrow SWIR bands at 1,200, 1,300 and 1,665 nm.

Each band carries its own center tolerance, from ±2 nm on narrow bands to ±10 nm on the 250 nm visible band.

What to Specify

  • Center wavelength of each band, with tolerance
  • Width (FWHM) of each band
  • Minimum transmission in each band
  • Blocking OD and range between bands
  • Blocking range outside the outer bands
  • Angle of incidence and cone half-angle
  • Size, thickness and mounting

Choosing a Multiband Filter

Start from your sources. List each center wavelength and how wide its emission is; each band should cover one source with margin for its tolerance.

Check the gaps. Ask what blocking you need between bands and over what range. If a band sits close to its neighbor, expect softer blocking between them.

Mind the angle. Tilting moves every band to shorter wavelengths, and each band moves in proportion to its wavelength: at the same tilt, an 850 nm band moves about 1.6 times as far as a 525 nm band.

Standard Multiband Filters

Model Bands (nm) Transmission AOI
Multi-450/555/685 450 / 555 / 685 TAvg > 90% in each band 0°
Multi-650/850 650 / 850 TAvg > 90% in each band 0°
Multi-1200/1665 1,200 / 1,665 TAvg > 90% in each band 0°

For these three filters, band widths and blocking are shown on each filter’s measured curve.

More Multiband Designs

Design Center wavelengths (nm) FWHM (nm)
310 & 400 nm dual band 310 ± 2 / 400 ± 2 10 ± 2 / 20 ± 2
500 & 655 nm dual band 500 ± 2 / 655 ± 2 10 ± 2 / 20 ± 2
525 & 850 nm dual band 525 ± 10 / 850 ± 5 250 ± 20 / 50 ± 10
525 & 940 nm dual band 525 ± 10 / 940 ± 5 250 ± 20 / 50 ± 10
660 & 860 nm dual band 660 ± 5 / 860 ± 5 35 ± 5 / 50 ± 5
1,202 & 1,300 nm dual band 1,202 ± 5 / 1,300 ± 5 30 ± 5 / 30 ± 5
1,205 & 1,302 nm dual band 1,205 ± 5 / 1,302 ± 5 30 ± 5 / 30 ± 5
1,208 & 1,300 nm dual band 1,208 ± 5 / 1,300 ± 5 30 ± 5 / 30 ± 5
450 & 550 & 650 nm triple band 450 ± 5 / 550 ± 5 / 650 ± 5 30 ± 5 / 30 ± 5 / 30 ± 5
550 & 720 & 850 nm triple band 550 ± 5 / 720 ± 5 / 850 ± 5 30 ± 5 / 15 ± 5 / 30 ± 5

Transmission at least 90% per band; blocking OD2 to OD4 to order. Ask us for the curves.

More Multiband Designs

DesignCenter wavelengths (nm)FWHM (nm)
310 & 400 nm dual band310 ± 2 / 400 ± 210 ± 2 / 20 ± 2
500 & 655 nm dual band500 ± 2 / 655 ± 210 ± 2 / 20 ± 2
525 & 850 nm dual band525 ± 10 / 850 ± 5250 ± 20 / 50 ± 10
525 & 940 nm dual band525 ± 10 / 940 ± 5250 ± 20 / 50 ± 10
660 & 860 nm dual band660 ± 5 / 860 ± 535 ± 5 / 50 ± 5
1,202 & 1,300 nm dual band1,202 ± 5 / 1,300 ± 530 ± 5 / 30 ± 5
1,205 & 1,302 nm dual band1,205 ± 5 / 1,302 ± 530 ± 5 / 30 ± 5
1,208 & 1,300 nm dual band1,208 ± 5 / 1,300 ± 530 ± 5 / 30 ± 5
450 & 550 & 650 nm triple band450 ± 5 / 550 ± 5 / 650 ± 530 ± 5 / 30 ± 5 / 30 ± 5
550 & 720 & 850 nm triple band550 ± 5 / 720 ± 5 / 850 ± 530 ± 5 / 15 ± 5 / 30 ± 5

Transmission at least 90% per band; blocking OD2 to OD4 to order. Ask us for the curves.

Need a different band combination? Send us each center wavelength and width, the blocking you need between bands, the angle of incidence and the size, and we will reply with a quote and a recommended design. Contact us