Multi-1200/1665

Dual-band SWIR filter with more than 90% average transmission at 1,200 nm and at 1,665 nm.

Need a different size or spec? We make custom versions.

BANDOPTIC spectrum engine

Interactive Spectrum

Plot and compare optical filter spectra. Catalog curves digitized from the supplied PDFs are approximate references; request measured data for specifications.

Choose a filter from the catalog or upload a numerical CSV.

Request measured data

Catalog curves are approximate digital tracings of PDF graph images, not instrument CSV or guaranteed production-lot results. Some curves show only the plotted peak or cut-on edge; open the source graph for its full context. For approximate traces, OD values at or below 2% transmission are hidden because raster plots cannot verify blocking performance. Uploaded CSV files stay in your browser. Andover numerical curves will be added only when source data is available.

Technical Specifications

SpecificationValue
Pass band 1> 90% (average) at 1,200 nm
Pass band 2> 90% (average) at 1,665 nm
Band widthsAbout 40–80 nm per band; see the measured curve
BlockingOD > 3 (average) between the bands
Angle of incidence0°
Cone half-angle3.5°
SubstrateOptical glass (K9 / B270)
Thickness1.0 ± 0.1 mm
Dimensional tolerance+0 / −0.1 mm
Surface quality60-40 scratch-dig
Clear aperture≥ 90% of diameter

Sizes

Need custom requirements? We cut to your drawing.

SizeThicknessMount
Ø12.5 mm1.0 mmUnmounted
Ø25 mm1.0 mmUnmounted or ringed
12.5 × 12.5 mm1.0 mmUnmounted

Other sizes and shapes are cut to order.

Choosing This Filter

Multi-1200/1665 passes two narrow SWIR bands, at 1,200 nm and at 1,665 nm, each with more than 90% average transmission. A single InGaAs detector behind it sees two channels at once, which suits two-wavelength measurements: for example, one band on a material or gas absorption feature and the other as a reference. Band widths and blocking levels are shown on the measured curve, which we can send on request. It is designed for 0°. For single-band filters at these wavelengths, see BP1200/10,OD3 and BPF1660-15,OD3.

Customization Options

Need a different wavelength, width or blocking? We design it to order.

We can move the center wavelength anywhere from 200 to 2,500 nm, change the width, block deeper, up to OD6, or further into the infrared, and cut the filter to your size and thickness.

Tell us your light source, your detector and the numbers you need. We will reply with a recommended design and a quote, from a single prototype to production volumes.

See what we can make on our custom filters page. Learn more

FAQs

Can I tilt this filter?

A small tilt, up to about 2°, stays within spec. Beyond that, the edge moves to shorter wavelengths, and the further you tilt, the further it moves. If your design needs a tilt, tell us the angle and we will design for it.

How should I clean and store it?

Hold the filter by its edges. Blow off dust first, then wipe gently with lens tissue and reagent-grade isopropyl alcohol if needed. Store it dry, in its case, away from direct sunlight.

Can I get the measured curve with my order?

Yes. Ask for it when you order, and we include the measured transmission of your batch, as a chart and as a data file.

Don’t see the filter you need? Tell us about your system and we will suggest one or design it. Learn more