45DFG-HR1540/HT1565
Wavelength beamsplitter for 45° that reflects 1,540 nm and transmits 90% at 1,565 nm, separating two lines 25 nm apart.
Need a different size or spec? We make custom versions.
BANDOPTIC spectrum engine
Interactive Spectrum
Plot and compare optical filter spectra. Catalog curves digitized from the supplied PDFs are approximate references; request measured data for specifications.
Catalog curves are approximate digital tracings of PDF graph images, not instrument CSV or guaranteed production-lot results. Some curves show only the plotted peak or cut-on edge; open the source graph for its full context. For approximate traces, OD values at or below 2% transmission are hidden because raster plots cannot verify blocking performance. Uploaded CSV files stay in your browser. Andover numerical curves will be added only when source data is available.
Technical Specifications
| Specification | Value |
|---|---|
| Reflection | R > 95% at 1,540 nm |
| Transmission | 90% (average) at 1,565 nm |
| Angle of incidence | 45 ± 2° |
| Cone half-angle | 3.5° |
| Substrate | Optical glass (K9 / B270) |
| Thickness | 1.0 ± 0.1 mm |
| Dimensional tolerance | +0 / −0.1 mm |
| Surface quality | 60-40 scratch-dig |
| Clear aperture | ≥ 90% of diameter |
Sizes
Need custom requirements? We cut to your drawing.
| Size | Thickness | Mount |
|---|---|---|
| Ø12.5 mm | 1.0 mm | Unmounted |
| Ø25 mm | 1.0 mm | Unmounted or ringed |
| 12.5 × 12.5 mm | 1.0 mm | Unmounted |
Other sizes and shapes are cut to order.
Choosing This Filter
This 45° beamsplitter separates two near-infrared lines only 25 nm apart: it reflects 1,540 nm and transmits 90% at 1,565 nm. That kind of close spacing is needed in fiber-optic and laser systems where two channels in the 1.5 µm band have to be split or combined, for example a signal and a monitoring line. Edges this close together depend strongly on angle and polarization at 45°, so tell us your beam’s polarization and divergence. For reflecting everything from 1,538 nm upward, see 45D-HR1550.
Customization Options
Need a different wavelength, width or blocking? We design it to order.
We can move the center wavelength anywhere from 200 to 2,500 nm, change the width, block deeper, up to OD6, or further into the infrared, and cut the filter to your size and thickness.
Tell us your light source, your detector and the numbers you need. We will reply with a recommended design and a quote, from a single prototype to production volumes.
See what we can make on our custom filters page. Learn more
Related Filters
FAQs
Can I tilt this filter?
It is designed for 45°, the usual angle when a beam is split or combined. Its edges move with angle and are different for s- and p-polarized light, so mount it at 45° and tell us if your design uses another angle or a converging beam.
How should I clean and store it?
Hold the filter by its edges. Blow off dust first, then wipe gently with lens tissue and reagent-grade isopropyl alcohol if needed. Store it dry, in its case, away from direct sunlight.
Can I get the measured curve with my order?
Yes. Ask for it when you order, and we include the measured transmission of your batch, as a chart and as a data file.
Don’t see the filter you need? Tell us about your system and we will suggest one or design it. Learn more